Please use this identifier to cite or link to this item: http://localhost:8080/xmlui/handle/123456789/4367
Full metadata record
DC FieldValueLanguage
dc.contributor.authorYadav, Ankit Kumar-
dc.contributor.authorGarg, Varun-
dc.contributor.authorGulati, Monica-
dc.contributor.authorBansal, Parikshit-
dc.contributor.authorBansal, Kompal-
dc.contributor.authorKaur, Puneet-
dc.contributor.authorSingh, Sachin Kumar-
dc.contributor.authorMittal, Amit-
dc.contributor.authorNarang, Rakesh-
dc.contributor.authorKumar, Bimlesh-
dc.contributor.authorPandey, Narendra Kumar-
dc.contributor.authorWadhwa, Sheetu-
dc.contributor.authorKhatik, Gopal Lal-
dc.contributor.authorBanerjee, Mayukh-
dc.contributor.authorMohanta, Souvik-
dc.contributor.authorSinha, Shubham-
dc.contributor.authorJyoti, Jivan-
dc.contributor.authorSom, Sananda-
dc.contributor.authorKapoor, Bhupinder-
dc.contributor.authorSingh, Saurabh-
dc.date.accessioned2019-12-24T05:54:13Z-
dc.date.available2019-12-24T05:54:13Z-
dc.date.issued2018-07-24-
dc.identifier.urihttp://localhost:8080/xmlui/handle/123456789/4367-
dc.description.abstractObjectives: The present study describes a disposable static diffusion cell for in vitro diffusion studies to achieve better results as compared to well existing Franz diffusion cell (FDC) in terms of the absence of bubbles, variable receptor compartment, ease of handling, and faster results. Materials and Methods: The cell consists of a cup-shaped donor compartment made of semi permeable that could be either cellophane membrane or, animal skin fitted to a rigid frame, which is supported on a plastic plate that contains a hole for the sample withdrawal. The receptor compartment is a separate unit, and it could be any container up to 500ml volume capacity. The most preferred receptor compartment is glass beaker. In the present study, goatskin was used as semi-permeable membrane and verification of its performance was carried out through diffusion studies using gel formulations of one each of the four-selected biopharmaceutical classification system (BCS) class drugs. Metronidazole, diclofenac sodium, fluconazole, and sulfadiazine were used as model drugs for BCS Class I, II, III, and IV, respectively. Results: The newly developed diffusion cell (NDDC) was found to provide faster and more reproducible results as compared to FDC. At the time interval of 24 h, the cell was found to exhibit a higher diffusion of metronidazole, diclofenac sodium, fluconazole, and sulfadiazine by 0.65, 0.65, 0.32, and 0.81 folds, respectively. The faster release obtained with NDDC was attributed to a larger surface area of skin as compared to that in FDC. Conclusion: It was concluded that better reproducibility of results could be achieved with NDDC.en_US
dc.language.isoenen_US
dc.publisherAsian Journal of Pharmaceutical and Clinical researchen_US
dc.subjectNewly developed diffusion cellen_US
dc.subjectFranz diffusion cellen_US
dc.subjectBiopharmaceutical classification systemen_US
dc.subjectMetronidazoleen_US
dc.subjectDiclofenac sodiumen_US
dc.subjectFluconazoleen_US
dc.subjectSulfadiazineen_US
dc.titleDesign and performance verification of newly developed disposable static diffusion cell for drug diffusion/permeability studies (Only Abstract)en_US
dc.typeArticleen_US
Appears in Collections:E-Publication



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.